C3 Data
Pyrometry compliance data
Metalark reads furnace status from C3 through C3's API, takes in C3's email reports, and imports C3 site reports, so pyrometry records stay in C3 and show up where the shop schedules, certifies and ships work.
Companies whose products work alongside Metalark in the heat treat shop. Each one does a job Metalark connects to rather than replaces, so a shop can keep the tools it already trusts.
Pyrometry compliance data
Metalark reads furnace status from C3 through C3's API, takes in C3's email reports, and imports C3 site reports, so pyrometry records stay in C3 and show up where the shop schedules, certifies and ships work.
The shop's admin enters the shop's own C3 login on Metalark's Settings screen, checks it with the Test C3 Login button, and imports the furnaces C3 tracks. No login is shared between shops, and the password is never shown or logged.
Per furnace:
A test type C3 does not track stays "not tracked"; it is never read as passing.
When a compliance screen opens, reusing the answer for up to two minutes. If C3 cannot be reached, the status is Unknown, and Unknown is never treated as a pass.
With the furnace gate, which each shop sets to off, warn or block. It checks the furnace when a load is scheduled or moved onto it, when a load plan is accepted, when a certificate is issued and when an order ships. It judges from Metalark's pyrometry records, which C3's exports and emails keep current, and the verdict at certificate issue is kept in the audit trail.
Furnace controls and load data
Metalark reads loads from SSi's Load Entry database, or through SSi's own SuperSystems.API, on the shop network. It only reads. Every five minutes it takes in each new load with its furnace, recipe and start and end times, adds the temperature trace when it reads through the API, and links the load to the work order by its shop order number, so the furnace record sits with the job it belongs to.
No. Metalark only reads from SSi: read-only queries against the Load Entry database, or read requests to SuperSystems.API. We ask each shop to give Metalark a database login that can only read, so SSi's side enforces it as well.
By the shop order number entered on the load in SSi, matched to the work order's number in Metalark. A load with no number Metalark recognises is listed as unmatched, and an operator links it to the right job by hand.
Nothing is lost. The next run, five minutes later, looks at the same seven days again and takes in whatever it missed. The live floor view falls back to the loads already stored, and says so.
Load times are shown in the shop's own time zone, and temperatures are converted to Fahrenheit, whatever SSi stores.
Furnace platform and process data
Metalark reads finished jobs and alarms from QMULUS through Nitrex's REST API, using an API key the shop creates in QMULUS for a read-only user and can revoke at any time. Every request is a read; Metalark never writes to QMULUS. Every fifteen minutes each finished job becomes a furnace batch in Metalark with its recipe, start and finish and process traces, linked to the work order by its shop order number, and QMULUS alarms are recorded against the furnace.
No. Every request Metalark makes to QMULUS is a read. The key the shop creates should belong to a read-only user, so QMULUS itself would refuse anything else.
QMULUS refuses the request and Metalark records that the key was refused, without importing anything. Jobs that finished in the meantime are picked up on the first run after a working key is entered.
QMULUS sends times in UTC; Metalark shows them in the shop's own time zone. Temperatures are requested in Fahrenheit, and each trace is kept at up to 5,000 points.
If your product serves heat treaters and you would like it to work with Metalark, email info@metalarkqms.com or call 713-305-9749.